Turbine Electric Fans for Over-the-road Trucks

A Unique System for Diesel Engine Cooling

Most over-the-road vehicles that benefit from ram air cooling (air forced through the radiator by the vehicle's motion) may use the Series 3000, 5500, 6000, or 6500 Turbine Electric Fans to replace their conventional belt-driven fans.

 

FEATURES

4 Pole Construction
Models availiable for 12 and 24 Volt Applications
Permanent Magnet
Totally Enclosed (Model 3000 open)
Telescopic Mounting
Optional Weatherproofing
Bi-Rotational (Will push or pull air)
Fan Blades made of Polypropylene or Delrin.
May be reduced in size by the purchaser
Duty Cycle  -  continuous air over
Fan Diameters  -  up to 29"
CFM Ratings up to 10125
Motor Output up to 1.25 HP
Easy Brush access (Not availiable on Model 3000)
Cat6.JPG (25728 bytes)
Rad6.JPG (21789 bytes)DualRad6.JPG (26634 bytes)

TWO SYSTEMS TO CHOOSE FROM

EFE can supply single or low profile dual fan assemblies. Single fan assemblies are recommended for difficult cooling applications that require the maximum amount of air flow. They are quickly installed since only one unit is required.

Diagram FPO 2.GIF (4349 bytes)

EASY INSTALLATION

Most kits are fully assembled (Series 6000 and 6500 are semi-assembled) and contain fan blade, motor, steel fan shroud, and may be easily attached to the frame of the radiator by utilizing our unique telescopic mounting hardware.

specA.gif (2567 bytes)
SPECIFICATIONS
Model # A Shroud
Diameter
Volts Maximum
Amps
Maximum
CFM (2)
B C D E (3)
Closed
E (3)
Open
Weight
Lbs.
3000-15JT (4) 16.50" 12 18 3000 3" 6.75" 6.5" 25" 40" 16
3000-21KT (4) 21.75" 12 20 4500 3" 6.75" 6.5" 25" 40" 18
3000-24MT (4) 24.75" 12 22 5000 3" 6.75" 6.5" 25" 40" 20
5500-21LT 21.75" 12 (1) 24 4500 3" 9.5" 4.8" 25" 40" 24
5500-24MT 24.75" 12 (1) 28 6000 3" 9.5" 4.8" 25" 40" 26
5500-26NT 26.00" 12 (1) 32 7400 3" 9.5" 4.8" 25" 40" 28
6000-21OT 21.75" 12 (1) 40 5500 3" 9.5" 6" 25" 40" 44
6000-24PT 24.75" 12 (1) 45 6300 3" 9.5" 6" 25" 40" 46
6000-26NT 26.00" 12 (1) 50 8000 3" 9.5" 6" 25" 40" 48
6500-21OT 21.75" 12 (1) 45 6200 3" 9.5" 8" 25" 40" 54
6500-24PT 24.75" 12 (1) 50 7000 3" 9.5" 8" 25" 40" 56
6500-26QT 26.00" 12 (1) 55 8800 3" 9.5" 8" 25" 40" 58
6500-28RT 28.00" 12 (1) 60 9000   10.5" 8" 25" 40" 65
6500-30ST 30.00" 12 (1) 70 10125   10.5" 8" 25" 40" 70
specE.gif (2390 bytes)(1) Also availiable for 24 volt applications.    (3) For horizontal mounting only.
(4) Open construction - not recommended for  (2) CFM at "0" Static Pressure
harsh enviroments.
LOW PROFILE AND DUAL FAN APPLICATIONS CHART  Patented*
Engine HP
Up To:
Gross Vehicle
Weight (Lbs.)
Minimum Radiator
Core Surface Area
Required for Installation
Minimum Clearance
Between Engine and
Radiator for Installation
Fan
Model
Fan
Shroud
Dia.
No. of
Fans
Required
250 under 40,000 34" x 18"   32" x 26" 7.5" 3000-15JT 17" 2
300 under 50,000 40" x 23"   38" x 27" 7.5" 3000-15JT
3000-21KT
17"
22"
1ea.
300 under 60,000 45" x 23"   44" x 28" 7.5" 3000-21KT 22" 2
350 under 60,000 39" x 28"   38" x 31" 10.5" 5500-21LT
3000-15JT
22"
17"
1ea.
350 under 80,000 45" x 23"   44" x 28" 10.5"
7.5"
5500-21LT
3000-21KT
22"
22"
1ea.
350 under 80,000 34" x 34" 7.5" 3000-15JTX 17" 4
400 under 80,000 45" x 23"   44" x 28" 10.5" 6000-21OT 22" 2
400 under 80,000 50" x 25"   48" x 34" 10.5" 6000-24PT 25" 2

 

SINGLE FAN APPLICATION CHART Patented
Engine HP
Up To:
Gross Vehicle
Weight (Lbs.)
Minimum Radiator
Core Surface Area
Required for Installation
Minimum Clearance
Between Engine and
Radiator for Installation
Fan
Model
Fan
Shroud
Dia.
No. of
Fans
Required
200 under 30,000 23" x 23" 7.5" 3000-21KT 22" 1
250 under 40,000 23" x 23" 10.5" 5500-21LT 22" 1
250 under 50,000 25" x 25" 10.5" 5500-24MT 25" 1
300 under 60,000 30" x 30" 10.5" 6000-26NT 26" 1
350 under 60,000 32" x 32" 10.5" 6000-26NT 26" 1
350 under 80,000 32" x 32" 10.5" 6500-26QT 26" 1
400 under 80,000 32" x 32" 11.5" 6500-28RT 28" 1
450 under 100,000 37" x 37" 11.5" 6500-30ST 30" 1
*Units may be installed diagonally across radiator core.
Series 3000-5500-6000-6500 models are also availiable without fan shroud
and telescopic mounting hardware.
Custom designed units are availiable if space limitations are encountered.
On some applications, it may be necessary to use more than the
recommended number of fans.
The above information is provided as a guide. The user assumes all
responsibility in the final selection and use of products.

 

Home ] Autos and Pick-ups ] [ Trucks ] Off-Road and Buses ]

The content of Electric Fan Engineering is copyrighted and not for use unless authorized by Electric Fan Engineering
Copyright © 1998,1999 by Electric Fan Engineering Inc.