Picture Description:
Top Left: 5500-16JS
Top Right: 3000-21KT
Bottom Left: 5500-24NT
Bottom Right: 6500-30ST
Most over-the-road trucks can replace the conventional belt-driven fan with a turbine electric fan, provided the engine is under 450 hp and benefits from ram cooling. It should be noted that a successful installation depends on many critical factors, including the condition of the cooling system (engine must not overheat with the conventional fan), gross vehicle weight, alternator capacity and proper radiator core size. The electric fan must monitor water, charge air and air conditioning head pressure.
Our Technical Support Department should be contacted at 800-338-4120 to ensure proper fan selection.
FEATURES
EASY INSTALLATION
Most kits are fully assembled (Series 6000 and 6500 are semi-assembled) and contain fan blade, motor, steel fan shroud, and may be easily attached to the frame of the radiator by utilizing our unique telescopic mounting hardware.
HOW TO ORDER
For over-the-road trucks, select the correct model # and the number of units required from the appropriate application chart. Contact EFE for price, availability, or information on custom designed units.
| LOW PROFILE AND DUAL FAN APPLICATIONS CHART | ||||||
| ENGINE HP UP TO: | GROSS VEHICLE WEIGHT (LBS.) | MINIMUM RADIATOR CORE & SURFACE AREA REQUIRED FOR INSTALLATION | MINIMUM CLEARANCE BETWEEN ENGINE & RADIATOR FOR INSTALLATION | FAN MODEL | FAN SHROUD DIA. (Outside Diameter) |
NO. OF FANS REQUIRED |
| 250 | under 40,000 | 34" x 18" 32" x 26" | 7.5" | 3000-15JT | 17" | 2 |
| 300 | under 50,000 | 40" x 23" 38" x 27" | 7.5" | 3000-15JT 3000-21KT |
17" 22" |
1 ea. |
| 300 | under 60,000 | 45" x 23" 44" x 28" | 7.5" | 3000-21KT | 22" | 2 |
| 350 | under 60,000 | 39" x 28" 38" x 31" | 10.5" | 5500-21LT 3000-15JT |
22" 17" |
1 ea. |
| 350 | under 80,000 | 45" x 23" 44" x 28" | 10.5" 7.5" |
5500-21LT 3000-21KT |
22" 22" |
1 ea. |
| 350 | under 80,000 | 34" x 34" | 7.5" | 3000-15JTX | 17" | 4 |
| 400 | under 80,000 | 45" x 23" 44" x 28" | 10.5" | 6000-21OT | 22" | 2 |
| 400 | under 80,000 | 50" x 25" 48" x 34" | 10.5" | 6000-24PT | 25" | 2 |
| Units may be installed diagonally across radiator core. Series 3000-5500-6000-6500 models are also available without fan shroud and telescoping mounting hardware. Custom designed units are available if space limitations are encountered. On some applications, it may be necessary to use more than the recommended number of fans. The above information is provided as a guide. The user assumes all responsibility in the final selection and use of products. |
||||||
| SINGLE FAN APPLICATION CHART | ||||||
| ENGINE HP UP TO: | GROSS VEHICLE WEIGHT (LBS.) | MINIMUM RADIATOR CORE & SURFACE AREA REQUIRED FOR INSTALLATION | MINIMUM CLEARANCE BETWEEN ENGINE & RADIATOR FOR INSTALLATION | FAN MODEL | FAN SHROUD DIA. (Outside Diameter) |
NO. OF FANS REQUIRED |
| 200 | under 30,000 | 23" x 23" | 7.5" | 3000-21KT | 22" | 1 |
| 250 | under 40,000 | 23" x 23" | 10.5" | 5500-21LT | 22" | 1 |
| 250 | under 50,000 | 25" x 25" | 10.5" | 5500-24MT | 25" | 1 |
| 300 | under 60,000 | 30" x 30" | 10.5" | 6000-26NT | 26" | 1 |
| 350 | under 60,000 | 32" x 32" | 10.5" | 6000-26NT | 26" | 1 |
| 350 | under 80,000 | 32" x 32" | 10.5" | 6500-26QT | 26" | 1 |
| 400 | under 80,000 | 32" x 32" | 11.5" | 6500-28RT | 28" | 1 |
| 450 | under 100,000 | 37" x 37" | 11.5" | 6500-30ST | 30" | 1 |
| Units may be installed diagonally across radiator core. Series 3000-5500-6000-6500 models are also available without fan shroud and telescoping mounting hardware. Custom designed units are available if space limitations are encountered. On some applications, it may be necessary to use more than the recommended number of fans. The above information is provided as a guide. The user assumes all responsibility in the final selection and use of products. |
||||||
| SPECIFICATIONS | ||||||||||
| MODEL # | A. SHROUD DIAMETER | VOLTS | MAXIMUM AMPS | MAXIMUM CFM [2] | B | C | D | E [3] CLOSED | E [3] OPEN | WEIGHT LBS. |
| 3500-15JT | 16.50" | 12 | 18 | 3000 | 3" | 6.75" | 6.5" | 25" | 40" | 16 |
| 3000-21KT | 21.75" | 12 | 20 | 4500 | 3" | 6.75" | 6.5" | 25" | 40" | 18 |
| 3000-24MT | 24.75" | 12 | 22 | 5000 | 3" | 6.75" | 6.5" | 25" | 40" | 20 |
| 5500-21LT | 21.75" | 12 (1) | 24 | 4500 | 3" | 9.5" | 4.8" | 25" | 40" | 24 |
| 5500-24MT | 24.75" | 12 (1) | 28 | 6000 | 3" | 9.5" | 4.8" | 25" | 40" | 26 |
| 5500-26NT | 26.00" | 12 (1) | 32 | 7400 | 3" | 9.5" | 4.8" | 25" | 40" | 28 |
| 6000-21OT | 21.75" | 12 (1) | 40 | 5500 | 3" | 9.5" | 6" | 25" | 40" | 44 |
| 6000-24PT | 24.75" | 12 (1) | 45 | 6300 | 3" | 9.5" | 6" | 25" | 40" | 46 |
| 6000-26NT | 26.00" | 12 (1) | 50 | 8000 | 3" | 9.5" | 6" | 25" | 40" | 48 |
| 6500-21OT | 21.75" | 12 (1) | 45 | 6200 | 3" | 9.5" | 8" | 25" | 40" | 54 |
| 6500-24PT | 24.75" | 12 (1) | 50 | 7000 | 3" | 9.5" | 8" | 25" | 40" | 56 |
| 6500-26QT | 26.00" | 12 (1) | 55 | 8800 | 3" | 9.5" | 8" | 25" | 40" | 58 |
| 6500-28RT | 28.00" | 12 (1) | 60 | 9000 | 10.5" | 8" | 25" | 40" | 65 | |
| 6500-30ST | 30.00" | 12 (1) | 70 | 10125 | 10.5" | 8" | 25" | 40" | 70 | |
| (1) Also available for 24 volt applications. [2] CFM at '0' Static Pressure [3] For horizontal mounting only. |
||||||||||
Click on the images below for a larger view

Specifications